HP 1920S Prevent UDP Blat Attack

After installing a new HPE 1920S with Auto DOS enabled the on site SIP Phone system is unable to receive audio calls. This is due to the HP 1920S Prevent UDP Blat Attack protection feature filtering out UDP traffic.